Liquid ControLs GroupAn IDEX Fluid & Metering BusinessLectroCount® XL LED Remote DisplayE1615/E1616/E1617/E1618Installation & PartsOperation:
Model E1617 of the LectroCount XL LED Remote Display is designed to receive a calibrated (50 pulses per revolution) solid state quad
Model E1618 of the LectroCount XL LED Remote Display will accept the calibrated pulse output of the LCMag HML210 converter.
Model E1618 of the LectroCount XL LED Remote Display is designed to receive a calibrated single channel pul
AUTOMATIC SHUTOFF - WIRINGThe LectroCount XL LED Remote Display can be wired to turn on and shut off automatically. If wired f
The dual display kit allows two LectroCount XL LED Remote Displays to display the delivery volume of a single Le
The Rate of Flow Switch Kit is an optional accessory that toggles the LectroCount XL LED Re
The Reset Switch Kit (P. N. 82592) is required for the installation of XL LED Remote Disp
DECIMAL PLACE JUMPER SETTINGThe decimal place setting of model E1616 LectroCount XL LED Remote Displays is d
TORQUE SPECIFICATIONSWhen reassembling the LectroCount XL LED Remote Display, follow the torque pattern shown below to reattach t
BILL OF MATERIALS81866Unit of Measure Labels06639Nut #6-32 (4)08117Screw #6-32 x .375 (2)09363Washer, Neoprene (16) 09364Screw #10-24 x .5 (14)82596Li
INTRODUCTIONSafety Procedures ... 3General Information ...
© 2012 Liquid ControlsPub. No. 500364(6/2013)105 Albrecht DriveLake Bluff, IL 60044-22421.800.458.5262 • 847.295.1050Fax: 847.295.1057www.lcmeter.comT
SAFETY PROCEDURES! WARNINGNorth America - Installations must be in full accordance with the National Electrical Code (US) or the Canadian Electrical C
OVERVIEWThis manual provides instructions for the installation, operation, and maintenance of the LectroCount XL LED Remote Display
SPECIFICATIONS & DIMENSIONSTemperature Range • -40 to 158 ºF (-40 to 70 ºC)Environmental Rating• NEMA 4XInput Voltage• 9 to 28 VDC, 500 mA maximum
INSTALLATION OVERVIEW & GUIDELINESThe LectroCount XL LED Remote Display and accessories (whether supplied by Liquid Controls or other) must be ins
There are certain applications where sun or bright light may produce glare on the display. A Remote Display
Model E1615 of the LectroCount XL LED Remote Display is designed for use with a LectroCount LCR-II or LCR 600. L
Model E1616 of the LectroCount XL LED Remote Display is designed for use with a LectroCount LCR (CPU board 81547